HMI manufacturer and supplier today: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. Discover more info at human machine interface manufacturer.

Corresponding Functional Requirements: Gemerally, small plc have functions such as logic operation, timing and counting, which can be met for equipment that only needs to be controlled by switching quantity. For systems with switching control as the main and a small number of analog control, an enhanced plc with A/D and D/A conversion units and functions of addition and subtraction arithmetic operations and data transmission can be selected. For complex control, it is required to realized PID calculation, closed-loop control, communication networking and other functions, visual control scale and complexity, and choose mid-range or high-grade plc. However, medium and large PLC are more expensive and are generally used in large-scale process control and distributed control system.

Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.

Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted. Read even more details on mochuan-drives.com.

Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed

Multiple color of shell and panel cutout for selecting, it is more flexible to match different project to improve the overall aesthetics and practical. Suggestions and recommendations to our customers through over a decade field experience industry and industry solution through software and hardware, if you work with us. If require the special technology, special function, special size, special parameter, special color, shape or special performance of ihm, welcome contact us for ODM. Mochuan hmi panel manufacturers will be very seriously and give timely feedback.

The size range is 4.3inch, 7inch, 9.7inch, 10.1inch, 12inch and 15inch, with ethernet, RS485, RS232 and RS422 to meet different application using. If you have the requirement of HMI, it is good to description of your application and what function wanna realize, then the correct and the most suitable model will be recommended to you. Mochuan Drives offers three series of plc programmable logic controller, there are switch control and motion control with very strong power for choosing. Offering free software, demo, 36months warranty, mature solution. And one-to-one technical supporting online to fast solve the customer technical question. Supporting to take the video to solve the technical question, that is service do you need?

Selecting HMI screen hardware parameters, mainly look at the CPU running speed and the capacity of the memory. According to the project involves the amount of data exchange animation, the size of the pictures to choose the CPU and memory. When processing more data and picture format is large, needing to choose a fast running speed, memory slightly large HMI. For example, Mochuan 15.6Inch MC-H156E, 7Inch MC-H070CWE, MC-H070CW with 1GHz CortexTM-A7 in CPU. And 10.1Inch MC-H100C, MC-H100CWE with 1GHz cortexTM-A7 and 4GB Flash memory. In addition, also needing to consider the functional requirements needed in the project, such as, how to achieve the multi-level tital pop-up, whether the screen display meets the customer’s need…etc.

Electrical cabinets are integrated cabinets used to accommodate electrical or various electrical equipment used as a carrier for electrical control equipment. It can provide strong protection against water, dust and electromagnetic interference to the stored objects. In the era of big data and the construction of intelligent industry, electrical cabinet control equipment is also playing a very important role. How can we better control the electrical equipment in the harsh environment of the electrical room? Here we recommend Mochuan drives industrial hmi touch panel for embedded installation.

Human-machine interfaces exist in all areas where human-machine information exchange is involved. A large number of industrial and commercial use, a simple distinction between “input” (Input) and “output” (Output) two, input refers to the operation of machinery or equipment by people, such as handles, switches, doors, instructions (orders) issued or maintenance, and output refers to the machinery or equipment issued by the notice, such as failure, warning, operating instructions tips, etc., a good human-machine interface will Help users more simple, more correct, more rapid operation of machinery, but also to maximize the performance of machinery and extend the service life, and the market refers to the human-machine interface is more narrowly defined in the software user-friendly operating interface.